- Shot point or Inline, Crossline: Type, Byte pos., Min, Max, and Step can be adjusted
- Scaler (X,Y): Value can be adjusted; Type is fixed to Integer16 and Byte pos. is fixed to the two bytes immediately preceding X
- X: Type and Byte pos. can be adjusted
- Y: Type is fixed to the same as X and Byte pos. is fixed to the corresponding bytes immediately succeeding X
- Z: Type, Byte pos., Min, Max, and Interval can be adjusted
Import 2D seismic
Make sure you have read about the different elements of the import menu above, before you read this section.
Import of 2D seismic can be done in 4 steps:
- Browse for the seismic file.
- Analyze the file, looking for anomalies.
- Scan the file to make sure the settings are correct.
- Execute the import.
Step 2 and 3 are explained in detail below.
Analyze file
The analyze process scans the SEG-Y file looking for anomalies:
...